PLA435-5CM
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| Schuko | 16 A | 3 m | 5 x Schuko | 19 inch |
REMARKS:
with Current Meter
PLP1006
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 2p+E | 16 A | 3 m | Front: 2 x Schuko Rear: 8 x Schuko | 19 inch |
REMARKS:
with Current Meter
PLH1182-12CM
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| Schuko | 16 A | 3 m | 12 x Schuko | 1182 mm |
REMARKS:
with Current Meter
PLA435-8CM
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| Schuko | 16 A | 3 m | 8 x C13 | 19 inch |
REMARKS:
with Current Meter
PLA435-9CM
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 2E+P | 16 A | 5 m | 9 x C13 | 19 inch |
REMARKS:
with Current Meter
PLP1014
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 2p+E | 16 A | 3 m | Front: 3 x C13 Rear: 9 x C13 | 19 inch |
REMARKS:
with Current Meter
PLP1020
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| GST 18/3 | 2 x 16 A | - | Front: 2 x Schuko Rear: 6 x C13, 2 x C19, 2 x GST18 | 19 inch |
REMARKS:
Dual Power Monitoring Unit (DPMU)
PLP1024
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 2p+E | 32 A | 3 m | 8 x Schuko | 19 inch |
REMARKS:
2 groups of 16A
2 x Current Meter
PLH1130-16-2CM
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 2p+E | 32 A | 3 m | 16 x C13, 2 x C19 | 1130 mm |
REMARKS:
2 groups of 16A
2 x Current Meter
PLP1022
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 2p+E | 32 A | 3 m | 6 x C19 | 19 inch |
REMARKS:
2 groups of 16A
2 x Current Meter
PLP1023
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 2p+E | 32 A | 3 m | 2 x C19, 2 x GST18 | 19 inch |
REMARKS:
2 groups of 16A
2 x Current Meter
PLD1020
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| 2 x CEE 2p+E | 2 x 32 A | 3 m | Rear: 4 x C19, 4 x GST18 | 19 inch |
REMARKS:
4 groups of 16A
4 x Current Meter
Dual Power Monitoring Unit (DPMU)
PLP1101
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 4P+E | 16 A | 3 m | 6 x C19 | 19 inch |
REMARKS:
3-phase 16A
3 x Current Meter
PLP1103
| INPUT CONNECTOR | MAX. INPUT CURRENT | CABLE LENGTH | OUTLETS NO/TYPE | LENGTH HOUSING | SPEC. SHEET |
|---|---|---|---|---|---|
| CEE 4P+E | 16 A | 3 m | 3 x GST 18/3 | 19 inch |
REMARKS:
3-phase 16A
3 x Current Meter