PLA435-5CM

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
Schuko 16 A 3 m 5 x Schuko 19 inch PLA435-5CM.pdf

REMARKS:
with Current Meter

PLP1006

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 2p+E 16 A 3 m Front: 2 x Schuko
Rear: 8 x Schuko
19 inch PLP1006.pdf

REMARKS:
with Current Meter

PLH1182-12CM

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
Schuko 16 A 3 m 12 x Schuko 1182 mm PLH1182-12CM.pdf

REMARKS:
with Current Meter

PLA435-8CM

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
Schuko 16 A 3 m 8 x C13 19 inch PLA435-8CM.pdf

REMARKS:
with Current Meter

PLA435-9CM

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 2E+P 16 A 5 m 9 x C13 19 inch PLA435-9CM.pdf

REMARKS:
with Current Meter

PLP1014

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 2p+E 16 A 3 m Front: 3 x C13
Rear: 9 x C13
19 inch PLP1014.pdf

REMARKS:
with Current Meter

PLP1020

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
GST 18/3 2 x 16 A - Front: 2 x Schuko
Rear: 6 x C13, 2 x C19, 2 x GST18
19 inch PLP1020.pdf

REMARKS:
Dual Power Monitoring Unit (DPMU)

PLP1024

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 2p+E 32 A 3 m 8 x Schuko 19 inch PLP1024.pdf

REMARKS:
2 groups of 16A
2 x Current Meter

PLH1130-16-2CM

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 2p+E 32 A 3 m 16 x C13, 2 x C19 1130 mm PLH1130-16-2CM.pdf

REMARKS:
2 groups of 16A
2 x Current Meter

PLP1022

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 2p+E 32 A 3 m 6 x C19 19 inch PLP1022.pdf

REMARKS:
2 groups of 16A
2 x Current Meter

PLP1023

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 2p+E 32 A 3 m 2 x C19, 2 x GST18 19 inch PLP1023.pdf

REMARKS:
2 groups of 16A
2 x Current Meter

PLD1020

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
2 x CEE 2p+E 2 x 32 A 3 m Rear: 4 x C19, 4 x GST18 19 inch PLD1020.pdf

REMARKS:
4 groups of 16A
4 x Current Meter
Dual Power Monitoring Unit (DPMU)

PLP1101

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 4P+E 16 A 3 m 6 x C19 19 inch PLP1101.pdf

REMARKS:
3-phase 16A
3 x Current Meter

PLP1103

INPUT CONNECTOR MAX. INPUT CURRENT CABLE LENGTH OUTLETS NO/TYPE LENGTH HOUSING SPEC. SHEET
CEE 4P+E 16 A 3 m 3 x GST 18/3 19 inch PLP1103.pdf

REMARKS:
3-phase 16A
3 x Current Meter